  te40 40w single output external power test & measurement/industrial series www.slpower.com te40 rev 1.3 11-jan-16 preliminary 1 features ? meets doe efficiency level vi requirements ? no load input power ? average efficiency ? up to 40w of ac-dc power ? universal input 90-264vac input range ? desktop and wall-plug versions ? meets ?heavy industrial? levels of en61000 emc requirements ? meets en55011/cispr11, and fcc part 15.109 class b conducted & radiated emissions, with 6db margin ? approved to en/iec/ul60950-1, 2 nd ed., am. 2 ? e-cap life of >8 years ? >1,000,000 hours mtbf ? 3 year warranty ? rohs compliant description a high performance ac to dc external power supply family designed for test & measurement and industrial applications. the te40a series models are compliant with efficiency level vi requirements per u.s. dept. of energy, as well as the heavy industrial levels of various en61000-4-x standards for emc. the te40a series models also meets class b conducted and radiated emissions per fcc part 15, en55022, and cispr22, with margin. model selection model output output ripple & line load overvoltage output input number volts current power noise 1 regulation regulation trip range connector configuration te40a1203f01 12.0v 3.40a 40w 120mv pk-pk 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class i desktop, iec60320 c14 receptacle te40a1803f01 18.0v 2.20a 40w 180mv pk-pk 1% 5% 120%-150% te40a2403f01 24.0v 1.70a 40w 240mv pk-pk 1% 5% 120%-140% te40a1203n01 12.0v 3.40a 40w 120mv pk-pk 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class i desktop, iec60320 c8 receptacle te40a1803n01 18.0v 2.20a 40w 180mv pk-pk 1% 5% 120%-150% te40a2403n01 24.0v 1.70a 40w 240mv pk-pk 1% 5% 120%-140% te40a1203q01 12.0v 3.40a 40w 120mv pk-pk 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii desktop, iec60320 c18 receptacle te40a1803q01 18.0v 2.20a 40w 180mv pk-pk 1% 5% 120%-150% te40a2403q01 24.0v 1.70a 40w 240mv pk-pk 1% 5% 120%-140% te40a1203b01 12.0v 3.40a 40w 120mv pk-pk 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii wall-plug, interchangeable blades2 te40a1803b01 18.0v 2.20a 40w 180mv pk-pk 1% 5% 120%-150% te40a2403b01 24.0v 1.70a 40w 240mv pk-pk 1% 5% 120%-140% te40a1203c01 12.0v 3.40a 40w 120mv pk-pk 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm straight barrel type, center positive class ii wall-plug, fixed north american blades3 te40a1803c01 18.0v 2.20a 40w 180mv pk-pk 1% 5% 120%-150% TE40A2403C01 24.0v 1.70a 40w 240mv pk-pk 1% 5% 120%-140% notes: 1 . m e a s u r e d a t t h e o u t p u t c o n n e c t o r , w i t h n o i s e p r o b e d i r e c t l y a c r o s s o u t p u t a n d l o a d t e r m i n a t e d w i t h 0 . 1 f c e r a m i c a n d 1 0 f l o w e s r c a p a c i t o r s . 2. standard models are fitted with north american blades. order blade kit kt-1027k for other blades (eu. uk, australia) 3. for eu fixed blades, replace ?c? in the model number with ?m?, for uk blades, replace ?c? with ?g?, for australia blades, replace ?c? with ?h?. 4. all specifications are typical at nominal input, full load, at 25 c ambient unless noted.
te40 40w single output external power test & measurement/industrial series www.slpower.com te40 rev 1.3 11-jan-16 preliminary 2 general specifications ac input 100-240vac, 10%, 47-63hz, 1 ? turn on time less than 700ms @115vac, full load input current 115vac: 1.2a, 230vac: 0.6a hold-up time 20ms min., at full load, 100vac input inrush current 264vac, cold start: will not exceed 40a overtemperature protection will shutdown upon an overtemperature condition, auto-recovery. input fuses 2.0a, 250vac overload protection 130% - 160%, hiccup mode earth leakage current i n p u t - g n d : < 5 0 0 a @ 2 6 4 v a c , 6 0 h z , n c output-gnd: <4ma@264vac, 60hz, nc short circuit protection hiccup mode, auto recovery. efficiency meets us doe efficiency level vi average efficiency levels overvoltage protection hiccup mode. see models chart for trip ranges. output power 40w continuous ? see models chart for specific voltage model ratings. isolation input-output: 4000vac input-ground: 1500vac output-ground: 1500vac no load input power <0.1w per doe efficiency level vi requirements safety standards en/csa/ul/iec 60950-1, 2nd edition, am 2 ripple and noise see models chart on pg 1. operating temperature -20c to +50c start up at -40c, full load, (warmup period before all parameters are within published specifications). output voltage see models chart on pg 1. temperature derating derate output power above 40c to tbd at 50c transient response 500 s response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ? i/ ? t< 0.2a/ s. max. voltage deviation is +/-3.5%. storage temperature -40c to +85c regulation see models chart on pg 1. altitude operating: to 5000m. non-operating: -500 to 40,000 ft. drop test 1.4m from table top to wooden platform, 6 faces. relative humidity 5% to 95%, non-condensing vibration operating: 0.003g/hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500hz. non-oper.: random waveform, 3 minutes per axis, 3 axes and sine waveform, vib. frequency/acceleration: 10-500hz/1g, sweep rate of 1 octave / minutes, vibration time of 10 sweeps / axes, 3 axes shock operating: half-sine, 20gpk, 10ms, 3 axes, 6 shocks total non-operating: half-sine waveform, impact acceleration of 100g, pulse duration of 6 ms, number of shocks: 3 for each of the three axis dimensions see outline drawings mtbf >250,000 hours, full load, 110 & 220vac input, 25 c amb., per telcordia 332 issue 6. weight 250g e-cap life >7 year life based on calculations at 115vac/60hz & 230vac/50hz, ambient 25c at 24 hrs per day, 365 days/year, 6 power up cycles per day. (@80% load for the 12v model) all specifications are typical at nominal input, full load, at 25 c ambient unless noted.
te40 40w single output external power test & measurement/industrial series www.slpower.com te40 rev 1.3 11-jan-16 preliminary 3 emi/emc compliance conducted emissions: en55011/cispr22 class b, fcc part 15.107, class b: 6db margin typ, at 115 and 230vac radiated emissions: en55022/cispr22 class b, fcc part 15.109, class b: 3db margin typ, at 115 and 230vac common mode noise: high frequency (100khz-20mhz): <40ma pk-pk electro-static discharge (esd) immunity on power ports: en55024/iec61000-4-2, level 4: +/- 8kv contact, +/- 15kv air, criteria a radiated rf em fields susceptibility en55022/en61000-4-3, 10v/m, 80mhz-2.7ghz, 80% am at 1khz electrical fast transients (eft) /bursts: en55024/iec61000-4-4, level 4, +/- 4kv, 100khz rep rate, 40a, criteria a surges, line to line (diff mode) and line to gnd (cmn mode) en55024/iec61000-4-5, level 4, +/-2kv dm, +/-4kv cm, criteria a conducted disturbances induced by rf fields en55022/iec61000-4-6, 3v/m ? level 4, 0.15 to 80mhz; and 12v/m) in ism and amateur radio bands between 0.15mhz and 80mhz, 80% am at 1khz rated power frequency magnetic fields en55024/iec1000-4-8, level 4: 30a/m, 50/60 hz voltage interruptions, dips, sags & surges en55024/iecen61000-4-11: --100% dip for 20ms, criteria a --100% dip for 5000ms (250/300 cycles), criteria b --60% dip for 100ms, criteria b --30% dip for 500ms, criteria a harmonic current emissions en55011/en61000-3-2, class a flicker test en61000-3-3 . all specifications are typical at nominal input, full load, at 25 c ambient unless noted. mechanical drawing iec60320 c14 receptacle, 2.5 x 5.5 x 9.5mm barrel connector interchangeable n.a. blade, 2.5 x 5.5 x 9.5mm barrel connector notes: 1. all dimensions in mm. 2. interchangeable blade models come with north american blade fitted. for other blades (eu, uk, aust.) order blade kit kt1027k. 1 4 5 0 5 0 54 9 5 . 5 9 6 55 1 4 5 0 5 0 33.6
te40 40w single output external power test & measurement/industrial series www.slpower.com te40 rev 1.3 11-jan-16 preliminary 4 connector information standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (ault #3), center positive. other standard options are listed below. the ?03? in the standard model number is replaced by the applicable digits below: efficiency level vi information: data sheet ? 2016 sl power electronics corp. the information and specifications contained herein are believed to be correct at the time of publication. however, sl power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifications are subject to change without notice. te40a series


▲Up To Search▲   

 
Price & Availability of TE40A2403C01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X